GOSSEN METRAWATT รุ่น PROFITEST PV
คุณลักษณะพิเศษ
คุณลักษณะทั่วไป
The differences ...
Why is measurement with capacitive load necessary?
On the one hand, measurement of characteristic curves for PV generators (modules, strings, arrays) must not be conducted too quickly (high dV/dt), because the measured characteristic curve may be changed in the case of rapid measurement (< 20 ms) due to the capacitive/inductive attributes of the generator or the test setup, in which case not only the characteristics of the PV generator are reflected in the measurement results. On the other hand, measurement must not be too slow either (> 1 sec.), because the danger of fluctuating radiant exposure is otherwise significantly increased, which would influence measurement results. This affects module temperature as well, which reacts relatively sluggishly but nevertheless can change within a matter of seconds.
Patented calculation process for determining the generator’s internal series resistance based solely on a measured characteristic I-U curve:
This resistance is the physical result of the material used to manufacture the module, as well as its layout and wiring connections, and normally has a constant value. For example, it amounts to roughly 1 ? for crystalline modules and more than 2 ? for thin-film modules. As of recently, measurement of internal series resistance can be performed with instruments from the Profitest PV product range. Only a single characteristic I-U curve has to be traced at the module for this purpose. On the basis of this characteristic curve, the instrument automatically calculates RS, as well as peak power PPK and parallel resistance RP.
Theoretically anticipated internal series resistance RS can be calculated. For example, this is possible with the software if the the following characteristic STC values are known for the module: Uoc, Isc, UMpp and IMpp.
The calculated RS value can then be compared with the measured value, which is read out by a Profitest PV after curve tracing. If the measured value is too high, wiring must be inspected for interruptions, corrosion, connection errors and underdimensioning.